Vacuum toilet systems
EVAC 2000P

PROPERTIES
Operates with a constant pre-set vacuum level controlled by a vacuum switch connected to the retention tank. The flushing and the evacuation of the toilet bowl is completely managed by a vacuum operated pneumatic controller. The electric control for the remaining systeSpeichernm is reduced to support some solenoid valves and the tank level indication. The water consumption per flush can be minimized to 0.5 liter. This system is a very interesting cost efficient and simplified alternative to the EVAC 2000E. It shows a high grade of reliability.The system components are well proven and in operation in more than 700.000 Evac toilet applications (marine, building, train).

 
1 Suction protection
2 Outlet valve
3 Vaccum operated pneumatic controller


Details


HOW IT WORKS
Vacuum is constantly kept in the retention tank. An air ejector creates the vacuum energy guided by a pressure switch. The toilet flushing and evacuation are effected by vacuum and compressed air. No electrical supply to the toilet unit is needed.The retention tank can be supplied insulated and electrically heated. Sensors connected to the tank monitor the level of collected sewage.


GENERAL TECHNICAL DATA

Measurements
Dimensions:
different types available
Max. lift above toilet outlet:
2 m (with 4 m horizontal piping)
Max. horizontal piping run (toilet to tank):
tested to 14 m with a lift of 0.5 m
 
Material
Bowl assy:
Stainless steel
 
Supplies
Compressed air:
500-1000 kPa, filter: 7 μm max. grain size
Voltage:
24 V DC (+/- 30 %)
 
Consumption
Air:
approx. 50 liter expanded air per flush
Water:
approx. 0.5 liter per flush
 
Connection
Air:
G1/4“
Water:
G1/2”
Discharge: